RSD LUNG/ CHEST PHANTOMS |
|
Lung/Chest with removable diaphragm and lung pair insert. |
|
Low Contrast & High Contrast |
The next best thing to human lungs for radiographic
studies
Developed in conjunction with the University of California at Irvine's
Department of Radiological Sciences, the Alderson Lung/Chest Phantom is a
specialized phantom, providing a high degree of realism in chest
radiography.
The
Alderson Lung/Chest Phantom extends from the neck to below the diaphragm. It
is molded about an RSD “Superhuman" male skeleton, corresponding to the
external body size of a patient, 5'9" (175 cm) tall and weighing 162
lbs. (73.5 kg). RSD materials are equivalent to natural bone and
soft-tissues. Animal lungs are selected to match the size of an adult male. Lungs
are fixed in the inflated state and are molded to conform to the pleural
cavities of the phantom. The pulmonary arteries are injected with a
blood-equivalent plastic. The
Lung/Chest Phantom with simulated left coronary artery reveals several areas
of coronary artery irregularity and narrowing. To
demonstrate different pathological conditions, five standard pathologies are
available:
1. Two
contiguous 0.5 cm nodules at the tip of the first left rib. 2. A
0.6 cm nodule superimposed with large vessel in the left lower lobe. 3. A
1.5 cm nodule, left mediastinal shadow. 4. A
0.6 cm nodule blending in with the right pulmonary artery. 5.
Pneumonia in the right lower lobe. (Custom
pathologies are available upon request) The
Lung/Chest Phantom is available either with the diaphragm permanently sealed
to the interior of the phantom, fixing the lungs in place, or with a
removable diaphragm, which permits the interchange of lungs, and provides an
unlimited number of configurations and disease simulations. All models are
available with blood-equivalent pulmonary arteries, or with low or high
contrast media added. |
ORDERING INFORMATION |
|
MODEL |
DESCRIPTION |
RS-310 |
Lung/Chest Phantom with permanently sealed diaphragm |
RS-315 |
Lung/Chest Phantom with permanently sealed diaphragm and left coronary
artery |
RS-320 |
Lung/Chest Phantom with removable diaphragm, lung pair insert without
coronary artery |
RS-330 |
Lung/Chest Phantom with removable diaphragm, lung pair insert with
coronary artery |
RS-340 |
Lung pair insert without coronary artery |
RS-345 |
Lung pair insert with coronary artery |
|
Note: All Lung/Chest Phantoms are available with blood-equivalent
pulmonary arteries, or with high or low contrast media added. Please specify
when ordering. |
© Elimpex-Medizintechnik, Spechtgasse 32, A-2340
Moedling, Austria
phone +43-2236-410450